Showing posts with label mag gage. Show all posts
Showing posts with label mag gage. Show all posts

Tuesday, August 5, 2014

What Materials have was in a Hair Dryer?

photo from: gamaprofessional.com
Hairdryers are convenient hair home appliances having a simple construction. Hairdryers are put together from many parts; however the two primary parts really are a heating source along with a fan to blow the hot air. Through the years, the types of hair hairdryers have transformed, however the mechanics haven't.

Coiled Metal Wire

•           The heating unit produces the new air that dries the wet hair. In many hairdryers, the heating unit is really a coiled metal wire. This wire is generally made from a nickel and chromium alloy.

Fan

•           To obtain the hair dryer to blow the new ai, an admirer is required. All hairdryers have small fans whose rotor blades spin to create the ventilation.

Electrical Motor

•           A small motor is required to operate the fan.

Warmth Shield

•           The outdoors on most hairdryers consists of plastic. All hairdryers have warmth shields that offer insulation and stop the outdoors from the dryer from becoming hot and burning the consumer. The warmth shield is generally made from mica, a mineral.

Switching Systems

•           All hairdryers come with an off/on switch, additionally to 2 to 4 different switches for temperature configurations.

Polarized Plug

•           All hairdryers legally require polarized plugs. The kinds of plugs are known as ground fault circuit interrupters (GFCI) plus they help reduce the alterations of accidental electrocution and electric shock.


Hairdryers are utilized all over the world every day; however, many individuals who rely on them have no idea the way they work. The interior functioning of the hair dryer is really fairly simple, and could be divided into two elements, along with the outer spend, the controls, cord and plug. The various components of the hair dryer get together easily to rapidly and effectively work. For more useful information about mica shield feel free to visit Quest-Tec Solutions here.



Wednesday, June 11, 2014

Quest Tec Solutions Reaches More Customers Through Website

Having a website helps businesses reach out more customer. Quest Tec Solutions has made use of this new method in order to reach more potential customers. Visit us today at http://questtecsolutions.com/.

Quest Tec Solutions Introduces Cost Effective Water Level Indicator Products

Looking for cost effective water level indicators products? Quest Tec Solutions introduces this new product. Check it out at http://questtecsolutions.com/qts-products/


Friday, May 30, 2014

Testing Water Level inside a Boiler

Gauge glass is designed to show the level of water inside a boiler. The bottom of the glass must be at least three inches above the tubes in order to function well. The passage leading to the glass can be clear and water level can be tested accurately by taking these steps.

1. The top valve on column and top valve on glass must be closed, while the drain valve on glass should be opened. If water flows freely from drain, the water passages from boiler column and from column to glass are clear.

2. The bottom valves on column and glass should be closed, while the top valve should be open. If the steam flows freely from drain valve at bottom of glass, steam passage from boiler to column and from column to glass are clear.

3. The drain valves on glass are closed and drain valve on column are opened. If steam flows freely from column drain, the column itself can be conclude as crystal clear.

4. The column drain valves are closed and the bottom valves of column and glass are opened. The water will rise quickly to its correct level in the glass when the valve is closed. If action is sluggish, some obstruction may still be in the pipes or valves. The entire drain valve must be surely tightly closed and all other valves widely opened.

These are the proper procedures in testing the water level using a water column. With simply opening the drain valve and not touching any of other valves, the glass does not prove that both top and bottom connection are clear.

A water column is a hollow casting, or forging, connected by pipes at top and bottom to the boiler's steam and water spaces. For more information about water column and how it works, consult with the experts at Quest-Tec Solutions or visit their website at http://questtecsolutions.com/water-column-products.

Image Source - http://www.event-catering-hire.co.uk/images/burco%20electric.jpg

Monday, May 12, 2014

Understanding Transparent Level Gauges

A transparent level gauge is type of liquid level gauge with a different design and composition compared to reflex level gauge. It is appropriate for almost all installations and used in a wide variety of applications, and it permits the use of Mica shields for excellent glass protection.


How Transparent Level Gauge Works

Transparent level gauges employ two transparent glasses fitted with a liquid chamber on either side. The liquid level is indicated as a result of difference in the transparent properties of the two media. For water or steam applications, an illuminator is mounted on the rear side of the gauge with its light rays deflected upward into the water column. This enables the observer to see illuminated surface of the water as the light rays impinged on the surface of separation between water and steam are reflected back to the eye of the observer.

Choosing Transparent Level Gauges

Choose a transparent level gauge with liquid chambers that are made in one piece from a solid bar that have high physical properties at elevated temperatures. Make sure that they are accurately machined and ground to give perfect gasket seating for glass.

The cover of your level gauge should be made from high-grade materials such as a solid bar of steel and is jig drilled for interchange ability.

For the glass, make sure it is tempered, chemically stable, and absolutely transparent to make the device suitable for use at high pressures and temperatures, and will resist to chemical attack of all fluids. For steam and alkaline fluids, mica shields are recommended as protection to give longer life to transparent glasses.

Gaskets should be die-cut from highest quality material best suited for use with liquid being gauged and guaranteed perfect seal and absence of mechanical stress on the glass.

For more information about liquid level gauges and its various types including reflex and transparent level gauge, consult with the experts at Quest Tec Solutions or visit their website at http://questtecsolutions.com/reflex-level-gauge-vs-transparent-level-gauge.

Monday, May 5, 2014

Choosing Probes and Float Systems for Your Water Column

Water column instruments are devices designed to provide accurate pressure readings and help water level indicating operations run smoothly. The three primary components of water level indication systems include a water column, control unit, and remote display.
Photo credited to http://www.wika.co.za/upload/WIKA_Thumbnails/PIC_PR_LGG_de_de_24413_Product-Detail-Large.png

Choosing Probes for Your Water Column

Probe is an essential part of the water column. Here are some helpful tips that you should keep in mind when choosing probes for your water column.
  1. Electrical probe safety systems operate a larger number of functions than mechanical float safety. Probes may be positioned to actuate audible and/or visual alarms, fuel cut-out controls, pump controls, or other equipment. Thus, choose probes over mechanical floats.
  2. Exceptional probe sensitivity increases system reliability. Choose probes that feature high sensitivity and perform at the forefront of probe technology. In particular, make sure that ach probe model will respond to pure water of ultra-low conductivity (less than 1 micro mho) to complete circuits. In addition, choose probes with service life that is extended by using available renewing kits.
  3. Choose probes with an alarm system that provides an on/off actuation of high and low water alarms. Other features which you can look for include fuel cut-out trip, pump control, and PCB control unit.
Choosing Float Systems for Your Water Column
  1. Choose a reliable float that warns of high/low water levels in cast iron columns serving 0 to 250 PSI or forges steel columns serving pressures up to 900 PSI.
  2. Choose a mechanical float type alarm system that employs lightweight floats and responds to as little as one-quarter inch level variations. Alarm components sit high in the column, removed from corrosive agents and scale. Quality materials and design simplicity combine to minimize requirements for periodic adjustment and maintenance.
To know more information about water column, probes, and float systems, consult with the experts at Quest Tec Solutions, manufacturers of high-quality liquid level indicators and gauges. Visit their website at http://questtecsolutions.com/water-column-products.

Wednesday, April 30, 2014

The Uses of Liquid Level Indicators

Liquid level indicators are tools and devices designed to indicate the accurate level of a certain liquid, such as water, oil, fuel, and even corrosive substances. They are used in many industrial applications as many industries, companies, and businesses have the need to measure liquids.


Here is why liquid level indicators are important. Below are just some of the important uses of level indicators

1. A liquid level indicator can be used to determine the hydraulic properties of aquifers and identify results of aquifer tests.

2. A liquid level indicator can be used in mapping the altitude of the water table or potentiometric surface of other liquid and substances.

3. A liquid level indicator can be used in monitoring short-term and long-term changes in ground-water recharge and storage.

4. A liquid level indicator can be used in monitoring the effects of climatic variability and changes in the atmosphere.

5. A liquid level indicator can be applied in monitoring regional effects of ground water development and in indicating statistical analysis of water-level trends.

6. A liquid level indicator can be used in monitoring changes in the flow directions of liquid and other substances.

7. A liquid level indicator can be used in monitoring ground-water and surface-water interaction.

8. A liquid level indicator is ideally used in numerical or computer modeling of ground-water flow or contaminant transport.

9. A liquid level indicator enables identification of fluid level in high pressure, high temperature environments.

10. A liquid level indicator allows user to identify whether fuel in a vehicle is still sufficient or is nearing to empty.

Different applications require different types of liquid level indicators, particularly because each fluid is different in terms of temperature, composition, and toxicity. Without the use of proper level indicators, these liquids will not be measured accurately and may bring further damage to the solution. For more information about liquid level indicators, visit http://questtecsolutions.com/liquid-level-indicators.

Understanding Gauge Glass: Advantages and Disadvantages

A gauge glass, also called sight glass, is a device used in the measurement of liquid level. It is used for continuous indication of liquid level within a tank or vessel.In the gauge glass method, a transparent tube is attached to the bottom and top of the tank that is monitored. The height of the liquid in the tube will be equal to the height of water in the tank.

While gauge glasses are useful in measuring various types of liquid, using such device still pose certain advantages and disadvantages.

Advantages of Using Gauge Glass

1. With a gauge glass, direct reading is possible.

2. There are special designs of the device available for use up to 3000’c and 650 kg/cm^2.

3. Glassless designs are available in numerous materials for corrosion resistance, as well.

Disadvantages of Using Gauge Glass

1. The main disadvantage of using gauge glass is that it is read where the tank is located which is not always convenient, especially if the tank is remotely located to a distance not easily observed.

2. Since gauge glasses are located outside the tanks, the liquid in the glass may freeze in cold or extreme weather even though the liquid inside the tank does not, and thus, it may cause error in the reading.

3. Heavy, viscous liquids or liquids containing material which falls out of solution and clog the tube cannot be measured satisfactory by this device.

4. For long level spans, overlapping gauges are needed.

5. Finally, the accuracy and readability of the glass reading depends on cleanliness of glass and fluid.

There is a wide variety of gauge glasses available in the market, with different sizes and styles to meet the needs of equipment manufacturers and operators. To know more about gauge glasses and other liquid level indicating devices, consult with the experts at Quest Tec Solutions or visit their website at http://questtecsolutions.com/sight-glass-for-liquid-level-gauges.

Monday, April 28, 2014

Choosing Magnetic Gage

Magnetic gages provide one of the safest and most economical solutions in measuring and controlling yourliquid level measurement needs.They are used in many industries as they are generally safe and easy to use. Popular applications of magnetic gages include measurement of oil, water, acids, solvents, alcohol, refrigerants, caustics, and many more.


Although there are a lot of available magnetic gages in the market, you may want to consider some factors when choosing one.

1. Ease of use and installation – Choose a magnetic level gage that is easy to install and can be attached to nearly any type, size, or shape of liquid vessel or tank. Excellent models are designed to be easily connected to any type of processing equipment. For instances where you are not confident to install the device on your own, you can seek the assistance of professional installers at a minimum installation cost.

2. Safe – Technically, magnetic level gages are safer than the other types of liquid level indicators. However, do ensure that the device you are getting is one of the safest level gauge options on the market. Make sure that it can accommodate processes involving extreme pressure, high or low temperatures, excessive vibration, and corrosive or hazardous materials.

3. High visibility – Choose a magnetic gage designed with highly visible level indicator with the precise level measurement of a guided wave radar transmitter. Redundant level control can be achieved by adding a magnetostrictive transmitter or switch to the float chamber, providing independent technologies in one package.

4. Other wining features – Choose a magnetic gage with an innovative design that maximizes the magnetic field, wide flags and enhanced indicator view, an impact-resistant polycarbonate indicator window, corrosion-resistant moving parts, a modular design with many additional options, and safe, non-mercury switches.

These are just some of the features that you need to look for in magnetic gages before you make a purchase. For more information about liquid level indicators, consult with the experts at Quest Tec Solutions, or visit their website at http://questtecsolutions.com/magnetic-gauges.

A Guide in Selecting the Right Mag Gage for Specific Applications

A magnetic gage, also called mag gage, is a deviceused for obtaining the liquid level measurements inside processing vessels.Selecting the appropriate magnetic gage for a specific application is important. Use the following questions to review your requirements and establish a set of criteria for selecting the right mag gage for the application. Let this guide provide you with the key to help you make informed gauge decisions.

1. What is the process fluid?
What is the specific gravity?
What is the operating temperature?
What is the operating pressure?
Does it come with total, interface, or dual-level detection?

2. What are the gauge body details?
What is the material of construction?
What is the maximum pressure requirement?
What is the necessary level range (fluid fluctuation—often the vessel height)?
Does it have vent and drain connections?

3. What are the process connection details?
What is the size?
What is the tyoe?
What is the rating?
What is the orientation and position?

4. What type of indicator is preferred?
Does it have flag (orange/black, yellow/black, red/white)?
Does it have shuttle?
Does it have color indicators?

5. What measuring scale is required?
Does it measure level in inches, feet, and/or meter?
Does it measure volume in gallong, liters, or custom?
Does it measure percentage of liquid saturation?

6. What accessories are necessary?
Does it have switch function and type?
Does it have level transmitter?
Does it have frost extension (required for cryogenic applications)?
Does it do heat trace?
Does it have high or low-temp insulation?
Does it have magnetic traps?
Does it have gauge glass?

Let this serve as your question checklist when choosing a mag gage to purchase for any specific application. For more information about magnetic gauges and liquid level indicators, visit http://questtecsolutions.com/magnetic-gauges.